Product focus: Lighting fixtures EXL

Product focus: Lighting fixtures EXL

The lighting fixtures EXL are constituted by the enclosure EJB08 covered by the Ex component certificate. This lighting fixture may contain electrical and electronic equipment for lighting, control and visualization system; one fluorescent lamp or one or two LED lamps with related ballast/driver can be installed inside. An emergency version is also available and it is supplied with batteries and with related inverter.
High temperature Ni-Cd or Ni – Mh rechargeable batteries are needed.
The lighting fixtures EXL are intended for use on the surface (group II e III), in areas in which, during the normal activities, explosive atmospheres caused by gases, vapours, mists (G) and/or air/dust mixtures (D) are likely to occur (category 2).
The enclosures may have threaded holes on the walls, on the cover and in some cases on the bottom, allowing to screw the control or signaling accessories, or for the cable entry.
The lighting fixtures can also be supplied with exit signs and symbols, available in different languages (on request), or with the pictogram of “running man”.

Lamp characteristics
Fluorescent Lamp:
Vmax: 240V o 277V, according to the type of ballast/inverter installed into EXL;
Vn emergency unit: 3,6V – 6V;
P max: 8W.
LED lamp:
Vmax: 240V o 277V, according to the type of diver/inverter installed into EXL;
Vn emergency unit: 3,6V – 6V;
P max: 9,6W.

Type of protection Ex d IIB + H2 T6/T5 Gb
Ex tb IIIC T85°C/T100°C Db IP66
Degree of protection IP66°
Ambient temperature -60°C  +80°C